In 1948 Hendrik Casimir compared a perfectly conducting plate held close to one face of a perfectly conducting cavity with the same plate far away. In both positions the sum of half a quantum over every standing wave diverges; the difference of the two sums does not. The plate and the face attract with π²ℏc/(240 s⁴) per unit area, 0.013 dyne/cm² at a separation of one micron. FDT reads the gap as omnium, nowhere empty, and the plate and the face as clamps that fix which standing waves the gap holds. The clamped set holds less of the field’s residual than the free set, and less the narrower the gap: the pressure is that deficit. FDT returns Casimir’s value and the measured records unchanged, and names no live test.

The record

What the note computes

Casimir opens from two limits that he and Polder had published that year (Phys. Rev. 73, 360, 1948), obtained from the van der Waals–London forces corrected for retardation. An atom of static polarizability ϖ at a large distance 𝔯 from a perfectly conducting plate, and two such atoms at a large distance from each other, interact as

δE = −(3/8π) ℏc ϖ/𝔯⁴,δE = −(23/4π) ℏc ϖ1ϖ2/𝔯⁷. the two limits of reference 1)

In a communication to the Paris colloquium on the chemical bond in April 1948 he had shown that both also follow from the change of the electromagnetic zero-point energy, computed with classical electrodynamics. The note applies the same method to two perfectly conducting plates.

A cubic cavity of side 𝔏 with perfectly conducting walls holds a square plate of side 𝔏 parallel to one face. Casimir compares the plate at a small distance s from that face with the plate far away, at 𝔏/2; the note writes a for the separation. Between the plate and the face the standing waves have kz = πjz/s; to each wave vector belong two standing waves, and one when an index is zero. In both positions the sum of ½ℏω over every resonance frequency diverges. The difference of the two sums has a definite value, and the note takes it as the interaction between the plate and the face.

To reach a finite result the note multiplies the integrands by a function of k/km that equals one for k ≪ km, falls to zero as k/km grows and takes the value ½ at k = km. Its physical meaning, Casimir writes, is that very short waves, X-rays for instance, hardly see the plate, so their zero-point energy does not depend on where the plate stands. The Euler–Maclaurin formula reduces the difference to the derivatives of one integral at zero, the first zero and the third −4, and gives, as long as skm ≫ 1,

δE/𝔏² = −π²ℏc/(720 s³),force per unit area π²ℏc/(240 s⁴), 0.013 dyne/cm² at one micron

He concludes that two metal plates attract with a force independent of their material, as long as the distance is so large that, for wavelengths comparable with it, the penetration depth is small against it. He interprets the force as a zero-point pressure of electromagnetic waves, and calls its confirmation by experiment, small as it is, not unfeasible and of some interest. The note itself carries no measurement.

The FDT reading

0.1d No vacuum, P-2 clamps fix the modes, 0.1a the floor bounds every stroke

The gap is omnium

FDT has one substance, the omnium, and no variable of its chain E/m = c² = 1/(ε₀μ₀) = (d/t)² vanishes (0.1). ε₀ and μ₀ are the omnium’s response coefficients, and c is its strand rate, derived from them (0.1d). There is no vacuum (0.1d). The gap between the plate and the face is omnium; the same responses that give the strand rate enter the propagation law across it. The cavity between the face and the plate is the support region of the gap’s standing set, and the plate and the face are that set’s boundary data, never a vessel holding a field (0.1b). The plates are closed patterns of the omnium (I-5); the gap carries open strokes, one carrier in every geometry (I-2).

Two clamps fix the standing set

Mode geometry is set by the boundary conditions, the clamps, and not by the medium (P-2). The conducting walls are clamps, and the saturated nuclear cores of a plate are its pinning sites (P-3). The standing set the two clamps fix is

kx = πjx/𝔏,   ky = πjy/𝔏,kz = πjz/s,   k = √(k∥² + kz²). rebuilt from the note’s mode set

For a large plate the transverse wave numbers are continuous. The plane of zero longitudinal index keeps a whole transverse continuum with one wave per wave vector instead of two, which gives the zero term of the longitudinal sum its half weight. The two standing waves per wave vector are two standing patterns of the one carrier, counted as the note counts them.

The residual and the floor

The note gives each standing wave ½ℏω, its zero-point energy; a stroke delivered into a mode carries ℏω. FDT reads the half quantum as the residual of the one field in a medium in which no variable vanishes: no mode is empty. The chain fixes the energy, the time and the run of a stroke together, and a floor bounds every physical stroke below (0.1a):

Fmaxdmintmin = ℏ, a minimum, never a latticedmin = ctmin = 2ℓP,   tmin = 2tP.

A finite support therefore holds a finite set of wave numbers below the stroke bound, each sum of the two positions is finite, and the plates read their difference: no divergence at any scale (0.8). The half quantum is an energy per standing wave and changes with the wave; it is never the floor.

Two clamps and the residual between them. Left: the plate and the face clamp the standing set, drawn as its lowest three waves with nodes at the clamps; the free side carries the full set. Right, against the separation s: the magnitude of the pressure for ideal clamps, |P0| = π²ℏc/(240 s⁴); for gold clamps, the Lifshitz pressure with the plasma response at ℏωp = 9.0 eV and zero temperature; and for ideal clamps at 300 K, the Matsubara sum. The slider and the buttons set the separation; the readouts give |P0|, the two quotients, the lowest clamped standing wave c/(2s) and its occupation at 300 K. The gold and thermal quotients are tabulated from the same formulas as the analysis and its receipt.

P-2, 0.1a

The difference and the letting-go

The note needs its function of k/km to reach a finite result, and it reads it as the plate’s transparency to very short waves. FDT reads that letting-go, written 𝔤, as the plate’s own response, a measured property of the material: the plate fixes the standing waves it obstructs (P-2). The stroke bound of the floor and the plate’s response enter different operations. With the energy per unit area U = δE/𝔏², the expansion ratio 𝔳 = π/(skm), the squared wave number in gap units 𝔴, and 𝔉(j) = ∫j²∞ √𝔴 𝔤(𝔳√𝔴) d𝔴 the transverse integral at longitudinal index j, the Euler–Maclaurin formula gives

U = (π²ℏc/4s³) 𝔇,𝔇 = −𝔉′(0)/12 + 𝔉‴(0)/720      − 𝔉⁽⁵⁾(0)/30240 + …,𝔉′(0) = 0,   𝔉‴(0) = −4,𝔉⁽⁵⁾(0) = −24 𝔤″(0) 𝔳².

The third derivative fixes the energy, and holding the plate’s response fixed while the gap changes gives the pressure:

U0 = −π²ℏc/(720 s³),U/U0 = 1 − 𝔤″(0)𝔳²/7 + O(𝔳⁴),P/P0 = 1 − (5/21) 𝔤″(0)𝔳² + O(𝔳⁴).

The shape of the letting-go leaves only a remainder that falls as the square of 𝔳. A Gaussian and an exponential letting-go with the note’s value ½ at km, 2−(k/km)² and 2−k/km, give energy quotients of 1.00020 and 0.99993 at skm = 100; their curvatures at the origin have opposite signs, and so do their remainders. The leading coefficient is an identity on the note’s own inputs.

The pressure

Force times length is energy (I-1). The energy per unit area is the open line integral of the attraction’s magnitude, and the magnitude and the signed pressure along increasing s follow from it:

U0(s0) = −∫s0∞ |P0| ds,|P0| = ∂U0/∂s0 = π²ℏc/(240 s0⁴),P0 = −∂U0/∂s0.

The energy falls as the gap closes, so the plate and the face attract. The magnitude is 1.30 mPa at 1 µm, 13.0 Pa at 100 nm and 2.08 µPa at 5 µm, the note’s 0.013 dyne/cm² at one micron with the constants unrounded.

One field at two occupations

At a temperature T each mode holds (𝔫 + ½)ℏω with 𝔫 = 1/(eℏω/kBT − 1); the clamped and the free sets share the temperature and differ in their spectra. For ideal clamps the thermal crossover is at sT = ℏc/(2kBT), 3.82 µm at 300 K. Below it the pressure is P0 − aT⁴/3, with a = 4σSB/c and aT⁴/3 = 2.04 µPa: the free side’s field presses on a gap whose standing waves with a positive longitudinal index are too costly to fill, while its waves of zero longitudinal index stay open. Far above it the pressure tends to −ζ(3)kBT/(4πs³). The full sum gives P/P0 = 1.0016, 1.55 and 3.05 at 1, 5 and 10 µm. At 1 µm the lowest clamped standing wave with kz = π/s stands at 150 THz, with occupation 3.9 × 10⁻¹¹ at 300 K, against 4.33 THz where the occupation reaches one. The change of radiation energy enters the one stress tensor once, as the difference of the clamped and the free configurations (I-7, 0.5).

Real clamps

The note’s material independence holds while the penetration depth is small against the distance. A real plate clamps through its measured optical response. For gold with the plasma response at ℏωp = 9.0 eV, at zero temperature, the Lifshitz pressure is 0.44, 0.81, 0.89 and 0.98 of the ideal pressure at 100 nm, 500 nm, 1 µm and 5 µm; the plasma wavelength 2πc/ωp is 1.4 × 10² nm, and raising the plasma energy by 0.1 eV moves every quotient by less than 0.003. No form of the confinement operator enters these reflection coefficients (O-9). At room temperature the static transverse-electric reflection separates the two standard prescriptions for a normal metal: it vanishes for the Drude response and survives for the plasma response, and the precision record favours the plasma prescription. FDT reads a static magnetic field as a macroscopic helical density gradient (P-5); reflection from a static twist would need a clamp law for it, and the map from a circulating charge is not written here (O-6).

The whole geometry

The energy belongs to the clamp geometry as one settlement, never to a sum over pairs (0.1a). A perfectly conducting spherical shell has an outward stress, an energy of about +0.09 ℏc/(2Rsh) in Boyer’s calculation, where a sum of attractive pairs would pull inward. A sphere of radius Rsph over a plate, at s ≪ Rsph, feels Fs = 2πRsphU(s) at leading order, a limit of one geometry’s spectrum. Lamoreaux’s sphere and plate read a force integrated across a varying gap, and Bressi and colleagues’ parallel plates read the coefficient itself; their precisions apply to those two observables.

The atoms

The two limits of reference 1) are read under I-1’s one equation with four names and I-2’s one carrier. Two polarizability volumes and ℏc fix the inverse seventh power of the atom–atom limit. An I-1 evaluation at the atoms’ own inputs needs the map from a charge to an I-1 input, and none is written here (O-6).

How the plate lets go. Left: the two letting-go functions, each with the note’s value ½ at k = km, and the clamped wave numbers jπ/s as ticks along k/km, spaced π/(skm), each drawn as tall as the share the plate holds. Right, against skm on logarithmic axes: the remainder |δE/δE0 − 1| for both functions, summed exactly, and the remainder law 𝔤″(0)𝔳²/7, dashed. The slider and the buttons set skm; the readouts give the spacing and the energy and pressure quotients. As skm grows the clamped set grows dense on the scale where the plate lets go, and both quotients run to one.

P-2, 0.1a

What FDT predicts

Six candidates, none live

A divergence is a claim about observables, made only where FDT supplies an additional source, a constitutive input or a changed observable dictionary (Use 2). The analysis carried six candidates, each on a stated design, and its receipt retires all six: four fall below their decision thresholds, and two need a map the core does not yet carry. The analysis names no live test.

  1. DC-1
    The floor’s remainder. A plate whose letting-go has |𝔤″(0)| = 2 and approaches the floor’s bound km < 1/dmin = 3.09 × 10³⁴ m⁻¹ from below keeps a pressure remainder above (10/21)(πdmin/s)² = 4.9 × 10⁻⁵⁷ at 1 µm, where Casimir’s limit gives none. The decision threshold is 6.0 × 10⁻³; no material plate realises the specification, the note’s own being hardly an obstacle to X-rays.
  2. DC-2
    The transit across the gap. The open stroke crossing the gap runs at c (I-2). The standard excess for propagation normal to conducting plates, the Scharnhorst–Barton value, is 1.6 × 10⁻³² at 1 µm, against a threshold of 3.0 × 10⁻¹⁸; on the 3.34 fs transit that resolution is 3.3 × 10⁻³³ s, a reading no apparatus makes.
  3. DC-3
    A driven clamp and its inverse process. A flux-driven clamp on a superconducting circuit delivers mode pairs with no input, and the same pairs, injected, return power to the drive. 0.1a reads each direction as its own settlement from the state it starts from and gives neither rate; the measurements behind detailed balance stand in full (Use 6). No departure is placed on their quotient: delta 0 against a threshold of 0.175.
  4. DC-4
    Isotope and density. Plates of ⁷⁰Ge and ⁷⁶Ge against one sphere at 0.50 µm give a quotient of one in both readings: the ideal clamped pressure carries ℏ, c and s alone, and the density channel reaches the plates’ gravity. Two 1 mm slabs of natural germanium press on each other by gravity with 1.2 × 10⁻⁸ Pa, 5.7 × 10⁻⁷ of the ideal clamped pressure at 0.50 µm.
  5. DC-5
    The static reflection. The zero-frequency transverse-electric reflection of a normal metal needs a clamp law for a static twist (P-5), which needs the map from a circulating charge (O-6).
  6. DC-6
    The atoms. Reading the two atomic limits as I-1’s law at the atoms’ inputs needs the map from a charge (O-6).

Nine pieces sit outside the derivation and leave every result in it unchanged:

  1. O-9
    The spectrum. The confinement operator, its domains, boundary data and spectrum are to be derived; the plate’s optical response is measured, never derived from its closures.
  2. O-6
    The input maps. The maps from a charge, a circulating charge or a colour seat to an I-1 input are to be derived; DC-5 and DC-6 wait on them.
  3. O-5
    The remainders. The multipole and tidal remainders of the pair expression are to be derived; no closed form of it is written for slabs.
  4. O-8
    The aperture. The constitutive derivation of the aperture speed and index is to be derived; no aperture value enters the transit.
  5. O-1
    The core. The finite-core cutoff, the regular core chart or the outward phase-transfer law is to be derived.
  6. O-2
    The overlap odds. A geometrically constructed odds for the overlap-contrast application is to be derived.
  7. O-3
    The confinement odds. A canonical odds for the confinement application is to be derived.
  8. O-4
    The local profile. The local profile from the constitutive law with boundary, surface and core data is to be derived; no interior profile is used.
  9. O-17
    The pair measure. Host selection, the transport of the settlement measure and its extension to unequal weights or more patterns are to be derived; none enters the plates.

Readings declined

Use 6 Data yes, interpretation not necessarily

Standard reading

The van der Waals–London forces, corrected for retardation, are carried by an exchanged field.

FDT reading

The interaction is curvature and geodesic motion of one carrier at the finite strand rate (I-2, 0.1d).

The zero-point sums are unbounded, and the finite interaction comes from subtraction and a cutoff.

The floor bounds every physical stroke below, and the plates read the difference of two finite sums at finite cavity size (0.1a, 0.8).

The force the note calls a zero-point pressure of electromagnetic waves is the pressure of an empty vacuum.

It is the residual of the one field measured between two material clamps, in a medium that is nowhere empty (0.1, 0.1d, P-2, P-3).

Convergence

Use 2 Same source, same data

Hold fixed the plate’s optical response, the separation, the temperature and the normalization of each standing wave, and subtract the distant configuration at the same inputs. In the perfectly reflecting limit the pressure is the derivative of the rebuilt energy of the note, π²ℏc/(240 s⁴). At the measured boundary response it is the Lifshitz pressure, and with the sphere’s curvature kept it is the sphere observable; the measured records of Lamoreaux and of Bressi and colleagues enter at their own geometries and precisions. The map is the identity on the data.

No FDT channel changes these numbers. Reading the gap as omnium, the walls as clamps and the half quantum as the residual of one field changes no measured value: the plates’ gravitational window is 2.9 × 10⁻²⁸, the floor’s remainder 4.9 × 10⁻⁵⁷, and the stroke crosses the gap at c. Where FDT reads the record differently it declines the reading and keeps the data.